Pumptron Australia Pty Ltd 

 Automatic Protection & Control for Submersible Pumps   

                 

                  

Click on a Picture for further information on the model

 

User Instructions       Technical Hints         Installation Sites      

 

 NEW - SOFT START

All models Lead free                                                                                                                 All Models Pb free

 

Pumptron is an Australian designed and manufactured state of the art electronic device for the protection and control  of Submersible water pumps or any other applicable pump installation. Pumptron is the product of a research and development program (R&D) that lasted for more than six years of investigation in the field. It is a simple, cost effective protection and control unit that does away with the need for flow switches or pressure switches or probes immersed into the well or bore, which are expensive to install and tend to be unreliable.

Pumptron protects and control all known brands of submersible pumps, helical or impellers.

 

Easy to install

Ø      Connect mains power to the input.

Ø      and controlled power from the output to the pump.

Ø      No probes into the bore or flow or pressure switches are required.

Easy to adjust

A little screw is turned clockwise until a green light turns ON indicating the pump is detected and protected.

DETECTIONS

ü      Water in the bore.

ü      No water in the bore.

ü      Storage tank full (detecting switch required)

ü      Storage tank low or empty (detecting switch required)

ü      Iron oxide build-up.

ü      Water sediments build-up.

ü      Limit of lifting power versus depth.

ü      Mains surges.

ü      A phase drops out.*

ü      Repetitive starts caused by pressure switch

ü      Obstruction of water flow

ü      Starting peak current.

PROTECTION AND CONTROL

Interrupts power if:

  • The bore runs out of water.

  • Iron oxide or sediments are overloading the pump.

  • Storage tank is full.

  • Mains voltage is too high or too low.

  • The pump reaches its maximum lifting capacity to pump water according to depth.

  • Any of the phases drop  out (3 phase units)

  • The motor electrically leaks to ground.

  • Any mechanical abnormality alters the normal operation.

  • Starting current has increased.

The pump starts automatically:

  • After the water recovery timer lapses.

  • After a power blackout.

  • When a dropped out phase restores.*

  • When the storage tank level lowers.

Other

  • The pump starts instantly on power up, however it will stop immediately if any abnormality is detected.

  • Avoids unnecessary stops and starts due to power surges. This extends the pump’s life.

INDICATIONS by means of L.E.D. Lights

Red light ON = Power ON

Small Flashing red light = System Standby - Overload

Yellow light ON = Pump 10 seconds priming

Small Orange light ON* = Tank Full

Green light ON = Pump under Protected Operation

Small Green light ON* = Bore Water Recovery timer ON

 

* New 3 phase model.

                                      

MODELS:

1PH - for Single phase pumps.

1PH-SS - soft start for Single phase pumps (New technology)

3PH - for Three phase pumps.

 

          

          OPERATION:

Once the pump is started it will run continuously until water in the bore runs out. Pumptron senses this and stops the pump. The water recovery timer then starts to measure a pre-selected time period (set according to the bore water productivity) to allow the bore to refill. This recovery time can be set between 3 minutes and 24 hours.

When the selected recovery time lapses, the pump turns ON automatically and runs until the water is exhausted again.

                                  

If an overload is detected, Pumptron turns power OFF instantly and a red flashing light indicates the condition.  Pressing the Start/Reset button, or at the water recovery time lapse, Pumptron attempts to start; if the overload condition is still present will instantly to the Stand By condition and the warning light continues to flash. However if the  condition has disappeared, normal operation is resumed.

 

FLOAT SWITCH: When a pump is used to fill a tank or a dam or in a pressure system, a plug (connector supplied) is available to connect a float switch or any external level sensing device. When the tank is full the unit stops. When the water level drops the pump starts.

 

The system remains automatic and unattended.

 

          TECHNICAL - UNIQUE FEATURES:                          

100% SOLID STATE…

Pumptron does NOT use phase shift detection so is impervious to fast voltage surges. The pump does not stop and starts unnecessarily.

 

Switching ON and OFF is done using semiconductors.

 

Switching is done at the ZERO voltage cross over point of the AC. Pumptron detects when the AC sine wave is at zero volts and trigger the switching semiconductors only at that instance. This results in shock free switching thus providing protection to starter capacitors (condensers) and to the system itself.

Infrared light beams are used in the switching process. This provides high isolation between the low voltage electronics and the mains, making Pumptron very safe to use.

 

 DIMENSIONS;  

Width = 150mm,  Height = 80mm, Depth = 140mm.

          ELECTRICAL  CHARACTERISTICS:

Operating voltages

Single phase

120 - 240 VAC  50/60 Hz

 

Three phase

220 - 380 - 415 VAC  50/60 Hz

Load current handling

 Single phase

1 to 30 Amps

 

Three phase

1 to 30 Amps

Wiring connectors rate at input and output

 30 Amps

Electrical isolation between main and logic circuit

 7.5  KV via Infrared light beam.

       PUMPTRON, THE PERFECT SOLUTION

 

Please Click to Order

TOP OF  PAGE

Visitor No.  Hit Counter

Pumptron Australia Pty Ltd
PO Box 301
North Ryde, N S W,  1670

Australia

Management

19 Moores Road,

Glenorie,  NSW 2157

Humberto A Cravero 0404042272

hacravero@pumptron.com

Last Updated

02 Nov 2008

Phone: 61 2 96522286

Fax       61 2 96522283

Email: info@pumptron.com

PayPal  orders@pumptron.com